Microdot® Xtra Test Strips #200-50
  • Each Microdot® strip contains glucose dehydrogenase (Bacillus sp.) = 1 IU and other ingredients (mediator, NAD, lysing agents) = 200 µg
  • Apply capillary whole blood; strip chemistry creates an electrical current read by the meter
  • Plasma‑calibrated. Measurement range 20–525 mg/dL. Use only with Microdot® meters.
SKU:
788084
For Use With:
For Microdot Meters
QTY Per Sell:
50
Key Features:
  • GDH‑NAD chemistry
  • Plasma calibrated
  • Auto‑code/no coding required
  • Measurement Range:
    20–525 mg/dL
    Accuracy:
  • Correlation vs YSI R=0.977
  • 98% in Clarke A zone
  • Precision:
  • Within‑run CV ≤5.6%
  • Total precision CV ≈3–5%
  • Intended Use:
  • In vitro measurement of glucose in capillary whole blood
  • Not for newborn testing
  • Temperature & Humidity:
  • Use at 10–40°C (50–104°F)
  • RH 10–90%
  • Hematocrit Limits:
  • Hct 25–55% recommended
  • Outside may bias results
  • Interferences / Limits:
  • Vit C ok at normal levels; extreme may affect
  • Chol up to 500 mg/dL; triglycerides up to 3000 mg/dL
  • Storage Instructions:
  • Store as manufacturer directs; keep vial closed
  • Do not freeze
  • Packaging Details:
  • Vial of 50 (Mfr# 200-50)
  • Box of 7500 available (bulk)
  • Regulatory / Codes:
  • HCPCS: E0607
  • UNSPSC: 41116106
  • Manufacturer:
    Cambridge Sensors / Microdot®
    Manufacturer Links:
    Microdot (manufacturer product page)
    SKU:
    788084
    For Use With:
    For Microdot Meters
    QTY Per Sell:
    50
    ic__sync_id:
    4
    ic__id:
    8035
    Key Features:
  • GDH‑NAD chemistry
  • Plasma calibrated
  • Auto‑code/no coding required
  • Measurement Range:
    20–525 mg/dL
    Accuracy:
  • Correlation vs YSI R=0.977
  • 98% in Clarke A zone
  • Precision:
  • Within‑run CV ≤5.6%
  • Total precision CV ≈3–5%
  • Intended Use:
  • In vitro measurement of glucose in capillary whole blood
  • Not for newborn testing
  • Temperature & Humidity:
  • Use at 10–40°C (50–104°F)
  • RH 10–90%
  • Hematocrit Limits:
  • Hct 25–55% recommended
  • Outside may bias results
  • Interferences / Limits:
  • Vit C ok at normal levels; extreme may affect
  • Chol up to 500 mg/dL; triglycerides up to 3000 mg/dL
  • Storage Instructions:
  • Store as manufacturer directs; keep vial closed
  • Do not freeze
  • Packaging Details:
  • Vial of 50 (Mfr# 200-50)
  • Box of 7500 available (bulk)
  • Regulatory / Codes:
  • HCPCS: E0607
  • UNSPSC: 41116106
  • Manufacturer:
    Cambridge Sensors / Microdot®
    Manufacturer Links: