- Self-contained vial with Geobacillus stearothermophilus spore carrier and sealed media ampoule.
- Provides biological indicator (BI) results in 24 minutes when used with 3M™ Attest™ Auto-reader 490 or 490H (software v4.2.7+).
- Monitors dynamic-air-removal (pre-vacuum & SFPP) steam cycles at 132°C/270°F and 135°C/275°F.
- Chemical process indicator on cap changes pink to light/dark brown after steam exposure.
- SKU:
- 852219
- QTY Per Sell:
- 50
- Temperature Range:
- 270F (132C ) / 275F (135C)
- GTIN:
- 50707387762969
- Class:
- Class 1
- Indicator Change:
- Pink to Light Brown
- Sterilization Compatibility:
- Steam
- Key Features:
- 24-minute fluorescent BI result
- Brown cap with chemical indicator
- Self-contained vial with sealed media ampoule
- Technical Specifications:
- Monitors pre-vacuum & SFPP
- 132°C/270°F & 135°C/275°F cycles
- Requires 3M Attest 490/490H reader
- Active Organism:
- Geobacillus stearothermophilus
- Detection Method:
- Fluorescence (a-glucosidase/MUG)
- Optional pH color change (purple to yellow)
- Compatibility & Requirements:
- 3M Attest Auto-reader 490 or 490H
- Reader software v4.2.7 or greater
- Regulatory / Standards:
- FDA cleared; ISO 11138-1:2017 & 11138-3:2017 compliant
- Packaging Details:
- BOX: 50 per box
- CASE: 200 (4 boxes)
- Storage Instructions:
- Store at controlled room temperature; follow manufacturer IFU for use-by date
- Shelf Life / Expiry:
- Use-by date printed on BI label (UDI-compliant 2D barcode)
- Handling & Safety:
- Contains viable organisms
- Follow facility biosafety and IFU
- Manufacturer Links:
- 3M product page: 3M Attest Super Rapid Readout Biological Indicator 1492V
- SKU:
- 852219
- QTY Per Sell:
- 50
- Temperature Range:
- 270F (132C ) / 275F (135C)
- GTIN:
- 50707387762969
- Class:
- Class 1
- Indicator Change:
- Pink to Light Brown
- Sterilization Compatibility:
- Steam
- ic__sync_id:
- 8
- ic__id:
- 12889
- Key Features:
- 24-minute fluorescent BI result
- Brown cap with chemical indicator
- Self-contained vial with sealed media ampoule
- Technical Specifications:
- Monitors pre-vacuum & SFPP
- 132°C/270°F & 135°C/275°F cycles
- Requires 3M Attest 490/490H reader
- Active Organism:
- Geobacillus stearothermophilus
- Detection Method:
- Fluorescence (a-glucosidase/MUG)
- Optional pH color change (purple to yellow)
- Compatibility & Requirements:
- 3M Attest Auto-reader 490 or 490H
- Reader software v4.2.7 or greater
- Regulatory / Standards:
- FDA cleared; ISO 11138-1:2017 & 11138-3:2017 compliant
- Packaging Details:
- BOX: 50 per box
- CASE: 200 (4 boxes)
- Storage Instructions:
- Store at controlled room temperature; follow manufacturer IFU for use-by date
- Shelf Life / Expiry:
- Use-by date printed on BI label (UDI-compliant 2D barcode)
- Handling & Safety:
- Contains viable organisms
- Follow facility biosafety and IFU
- Manufacturer Links:
- 3M product page: 3M Attest Super Rapid Readout Biological Indicator 1492V